5 Series MSO Mixed Signal Oscilloscope

5 Series MSO Mixed Signal Oscilloscope

With a remarkably innovative pinch-swipe-zoom touchscreen user interface, the industry's largest high-definition display, and 4, 6, or 8 FlexChannel™ inputs that let you measure one analog or eight digital signals, the 5 Series MSO is ready for today’s toughest challenges, and tomorrow’s too. It sets a new standard for performance, analysis, and overall user experience.

Bandwidth

Up to 2 GHz

Record length

Up to 125 Mpoints

Analog channels

4 or 6 or 8

Digital Channels

Up to 64

More than just a new display and user interface. A new standard.

Get the big picture and take total control, with the 15.6 HD touchcreen display. Use the capacitive pinch-zoom-swipe touchscreen, front panel controls, or mouse to analyze and manage multiple signals without fighting through menus.

Don't run out of channels.

Available with 4, 6, or 8 FlexChannel inputs. Each can be used to look at 1 high-resolution analog waveform or look at 8 digital logic waveforms, just by changing the probe.

Let no detail go unseen, with up to 16 bits of vertical resolution.

Thumbnail

12-bit analog to digital converters deliver up to 16 bits of vertical resolution using advanced digital signal processing. See and measure small signal details, even if they're riding on large signals.

Buy what you need now. Add on as your needs change.

Thumbnail

Performance

  • Bandwidth up to 2 GHz
  • Record Length up to 125 Mpoints

Digital Inputs

  • TLP058 Logic Probes each provide 8 digital channels

Operating System

  • Add Windows OS to run PC software on the scope

Signal Generation

  • Add a built-in Arbitrary/Function Generator

Advanced Analysis

  • Serial Decode/Trigger support for key buses like I2C, SPI, USB 2, Ethernet, CAN, LIN, many others
  • Advanced Jitter Analysis

 

 Tektronix
5 Series MSO
Tektronix
MSO/DPO5000B
Keysight
S-Series
LeCroy
HDO6000A/HDO8000A
Rohde & Schwarz
RTO2000
Yokogawa
DLM4000 Series
 
Detailed Comparison----Fact SheetFact SheetFact Sheet--
Bandwidth350 MHz to 2 GHz350 MHz to 2 GHz500 MHz to 8 GHz350 MHz to 1 GHz600 MHz to 6 GHz350 MHz, 500 MHz
Upgradeable BandwidthYesNoYesNoYesNo
Analog Channels4, 6, or 842 or 44 or 82 or 48
Analog Sample Rate (All Channels)Up to 6.25 GS/sUp to 5 GS/sUp to 10 GS/sUp to 2.5 GS/sUp to 10 GS/s2.5 GS/s
Standard Record Length (All Channels)62.5 M25 M50 M50 M50 M25 M
Integrated Arbitrary/Function Generator50 MHz (opt.)------100 MHz (opt.)--
Digital Channels (MSO)Up to 64 (opt.)16 (opt.)16 (opt.)16 (opt.)16 (opt.)8 (std) / 24 (opt)
Operating SystemClosed Linux
Open Windows (opt.)
Open WindowsOpen WindowsOpen WindowsOpen WindowsClosed
Standard ProbesUp to 1 GHz Passive
< 3.9 pF Loading
Up to 1 GHz Passive
< 3.9 pF Loading
500 MHz Passive
9.5 pF loading
500 MHz Passive
10 pF loading
500 MHz Passive
10 pF loading
500 MHz
10.5 pF loading
Standard Warranty3 years1 year3 years3 years3 years?

Embedded Serial Bus Analysis

Thumbnail

Automatic serial bus decoding saves time and eliminates errors versus hand decoding. Serial bus triggering and search enable you to isolate events for system-level troubleshooting.

Highlights

  • I2C, SPI
  • CAN, LIN, FlexRay
  • I2S/LJ/RJ/TDM
  • USB 2.0, Ethernet

Automotive Serial Bus Analysis

Thumbnail

Car designers rely on serial buses for error-free communications between ECUs, sensors and actuators. They can also rely on the 5 Series MSO, equipped with CAN, LIN, and FlexRay decoding and triggering to be able to get a synchronized view of their systems.

Jitter Analysis

Thumbnail

Clocks are the at the head of every embedded system and digital communication link. Jitter and other clock distortion can impact system operation, and getting to the root cause can be challenging without the right analysis tools.

Highlights

  • Standard phase noise, TIE, and frequency plots and histograms
  • Optional advanced analysis with jitter decomposition and clock recovery

Power Electronics

Thumbnail

With up to 8 high-resolution channels and a wide range of available probing solutions, the 5 Series MSO is ideal for evaluating power supply sequencing, and digging into 3-phase power converters.

 

Data SheetSoftware Package / Software OptionDescriptionConfigure and Quote
Opt. 5-SRCOMP

RS-232/422/485/UART protocol trigger and decode of serial packet content

Contact Us
Opt. 5-SREMBD

I2C and SPI protocol trigger and decode of serial packet content

Contact Us
Opt. 5-SRENET

10BASE-T and 100BASE-TX protocol search and decode of serial packet content

Contact Us
Opt. 5-SRUSB2

USB 2.0 Low-Speed, Full-Speed, and High-Speed protocol trigger and decode of serial packet content

Contact Us
Opt. 5-WIN

Add solid state drive with Windows 10 license

Contact Us
Opt. 5-AFG

Add built-in Arbitrary/Function Generator

Contact Us
Opt. 5-DJA

Simplifies identifying signal integrity concerns, jitter and their related sources and provides the highest sensitivity and accuracy available for real-time oscilloscopes.

Contact Us
Opt. 5-RL-125M

Extend record length to 125 Mpoints/channel

Contact Us
Opt. 5-SRAUDIO

I2S, LJ, RJ, and TDM protocol trigger and decode of serial packet content

Contact Us
Opt. 5-SRAUTO

CAN, CAN-FD, LIN, and FlexRay protocol trigger and decode of serial packet content

Contact Us

Access Digital Channels

Upgrade Description Purchasing Details
TLP058 Logic Probe Each probe accesses 8 digital channels on any FlexChannel for any 5 Series MSO Request a quote on this probe

Add Instrument Functions

Upgrade Description Purchasing Details
SUP5-AFG Add arbitrary function generator Request trial license

Request a quote
SUP5-DVM Add digital voltmeter / trigger frequency counter Software upgrade license file provided upon registration.
Register now.
SUP5-RL-125M Extend record length to 125 Mpts / channel Request trial license

Request a quote
SUP5-WIN Add removable solid state drive with Windows 10 license installed. No trial available

Request a quote

Add Protocol Analysis

Upgrade Description Purchasing Details
SUP5-SRAERO Aerospace serial triggering and analysis (MIL-STD-1553, ARINC429) Request trial license

Request a quote
SUP5-SRAUDIO Audio serial triggering and analysis (I2S, LJ, RJ, TDM) Request trial license

Request a quote
SUP5-SRAUTO Automotive serial triggering and analysis (CAN, CAN FD, LIN, FlexRay) Request trial license

Request a quote
SUP5-SRCOMP Computer serial  triggering and analysis (RS-232/422/485/UART) Request trial license

Request a quote
SUP5-SREMBD Embedded serial triggering and analysis (I2C, SPI) Request trial license

Request a quote
SUP5-SRENET Ethernet serial triggering and analysis (10Base-T, 100Base-TX) Request trial license

Request a quote
SUP5-SRUSB2 USB 2.0 serial bus triggering and analysis  (LS, FS, HS) (?1 GHz model recommended for HS) Request trial license

Request a quote

Add Advanced Analysis

Upgrade Description Purchasing Details
SUP5-DJA Advanced jitter and eye analysis Request trial license

Request a quote
SUP5-PWR Power analysis Request trial license

Request a quote

Upgrade Bandwidth

Upgrade Description Purchasing Details
SUP5-BWxTy8 MSO58 bandwidth upgrade from x to y, where x and y are the hundreds of MHz
  • Up to 1 GHz upgrades can be performed in the field.
  • 2 GHz upgrade requires installation at a Tektronix Service Center via option IFC or IFCIN.
  • Bandwidth upgrades from 350 or 500 MHz, to 1 or 2 GHz also include one TPP1000 1 GHz passive probe per channel.
SUP5-BWxTy6 MSO56 bandwidth upgrade from x to y, where x and y are the hundreds of MHz
SUP5-BWxTy4 MSO54 bandwidth upgrade from x to y, where x and y are the hundreds of MHz
Low Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TAP1500

Active Probe: 1.5 GHz, 10X, Single-ended, TekVPI

Configure & Quote
TAP2500 Active Probe: 2.5 GHz, 10X, Single-ended, TekVPI Configure & Quote
Current Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TCP0020

Probe, AC/DC Current; 20 Amp; 50 MHz BW; TekVPI Interface; Certificate of Traceable Calibration Standard

Configure & Quote
TCP0030A

Probe, AC/DC Current; 30 Amp DC, DC TO 120 MHZ; with TekVPI Interface; Certificate of Traceable Calibration Standard

Configure & Quote
TCP0150 Current Probe: 20 MHz, 5 mA to 212 A, AC/DC, TekVPI Configure & Quote
High Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TDP0500

Differential Probe: 500 MHz, 5X/50X, +/- 42V, TekVPI

Configure & Quote
TDP1000

Differential Probe: 1 GHz, 5X/50X, +/- 42V, TekVPI

Configure & Quote
THDP0100

Differential PROBE; 100 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE

Configure & Quote
THDP0200

Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE

Configure & Quote
TMDP0200

Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL MEDIUM VOLTAGE PROBE;TMPD0200

Configure & Quote
Low Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TDP1500 Differential Probe: 1.5 GHz, 1X/10X, +/-8.5V, TekVPI Configure & Quote
TDP3500 Differential Probe: 3.5 GHz, 5X, +/- 2V, TekVPI Configure & Quote
Isolated Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TIVM1

Differential Probe; 1 GHZ, 1X/5X/10X/20X/50X, +/- 50V, TekVPI, 3 Meter Cable

Configure & Quote
TIVM1L

Differential Probe; 1 GHZ, 1X/5X/10X/20X/50X, +/- 50V, TekVPI, 10 Meter Cable

Configure & Quote
Logic Analyzer Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TLP058

8 channel general purpose logic probe for 5 Series oscilloscopes. Includes accessory kit.

Configure & Quote
Passive Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TPP0500B

Passive Probe: 500 MHz, 10X, TekVPI

Configure & Quote
TPP0500B

Passive Probe: 500 MHz, 10X, TekVPI

Configure & Quote
TPP0502

Passive Probe: 500 MHz, 2X, TekVPI

Configure & Quote
TPP1000

Passive Probe: 1 GHz, 10X, TekVPI

Configure & Quote
High Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TPP0850

High Voltage Probe: 800 MHz, 50X, 2.5 kV, Single-ended, TekVPI

Configure & Quote
Data SheetAccessoryDescription
HC5 Hard transit case for the 5 Series MSO
RM5 Rackmount kit for the 5 Series MSO
TitleTypeDate
How to Troubleshoot System Problems Using an Oscilloscope with I2C and SPI Decoding
Learn about the physical layers of the most common interchip buses - I2C and SPI - to enable you to troubleshoot bus problems or system issues.  Learn how to set up and interpret the results when you use automated decoding, triggering, and search on an…
Literature number: 55Z-61091-0
Application Note 02 Oct 2017
Characterizing and Troubleshooting Jitter with Your Oscilloscope
Gives examples of jitter analysis, from basic analysis to more advanced jitter decomposition techniques using the 5 Series Mixed Signal Oscilloscope on unmodulated clocks, spread spectrum clocks, and serial data.
Literature number: 55Z-61099-0
Application Note 02 Oct 2017
Troubleshooting USB 2.0 Problems with Your Oscilloscope
Learn the basics of the USB 2.0 physical layer to troubleshoot bus problems or system issues.  Learn how to set up and interpret the results when using automated decoding, triggering, and search on an oscilloscope equipped with USB 2.0 bus analysis…
Literature number: 55Z-61092-0
Application Note 02 Oct 2017
Verifying Power Supply Sequencing with an 8-Channel Oscilloscope
You’ll learn the basics of checking the power-on and power-off sequence of an AC-DC power supply, how to look at a bulk supply and various point of load regulators, and how an oscilloscope with more than 4 channels can expedite the process.
Literature number: 55W-61152-0
Application Note 28 Sep 2017
Troubleshooting Analog to Digital Converter Offset Using a Mixed Signal Oscilloscope
Shows how to perform quick checks on an Analog to Digital Converter (ADC) gain, offset and linearity, using a function generator and mixed signal oscilloscope (MSO).  The MSO is used to uncover a problem with offset error.
Literature number: 55W-61096-0
Application Note 19 Sep 2017
5 Series MSO MSO54, MSO56, MSO58
This manual provides theory of operation, service instructions, and a list of replaceable parts for the 5 Series MSO instruments.
Part number: 077130700
Service 08 Sep 2017
5 Series Mixed Signal Oscilloscope
For firmware version 1.0 and above. This document contains the specifications and performance verification procedures for the instruments.
Part number: 077130600
Performance Verification 28 Aug 2017
Understanding the impact of reference clock jitter on data jitter - and techniques for measurement and analysis
Electronic Products & Technology magazine
Technical Brief 22 Aug 2017
Yokogawa DLM4000 Series vs. 5 Series MSO Mixed Signal Oscilloscope Comparison
This fact sheet compares important specifications and features of the Tektronix 5 Series MSO Mixed Signal Oscilloscope to those of the Yokogawa DLM4000 Series
Literature number: 65W-61251-0
Competitive 04 Aug 2017
Identifying Setup and Hold Violations with a Mixed Signal Oscilloscope
Mixed signal oscilloscopes (MSOs) are able to capture both analog and digital representations of signals, making them well-suited for identifying problems with setup and hold times.  Learn how to use the digital capture functions of an MSO, as well as the…
Literature number: 55W-61095-0
Application Note 02 Aug 2017
Downloads
Download

Download Manuals, Datasheets, Software and more:

Go to top