DPO7000C Series

DPO7000C Series

Bandwidths up to 3.5 GHz and sampling rates up to 40 GS/s make the DPO7000C Series a natural choice for analyzing critical, high-speed signals. Over 30 analysis packages provide in-depth measurements for communications standards, jitter analysis, memory bus standards, vector analysis and more. Plus, the Windows operating system lets you run your own analysis software right on the instruments.
See all oscilloscopes »

Bandwidth

Up to 3.5 GHz

Analog channels

4

Record length

Up to 500
Mpoints

Sample Rates

Up to 40 GS/s

Advanced signal measurement and analysis

Thumbnail

Standard analysis tools include 53 automated measurements, measurement statistics, histograms, limit testing, advanced waveform math, user-definable filters and support for custom MATLAB and .NET math plug-ins. Specialized applications such as advanced jitter and eye analysis, and wideband RF analysis, can be added to extend the measurement capabilities.

Highlights

  • Characterize signal parameters with a suite of standard measurement tools
  • Advanced jitter and timing analysis characterizes signal integrity issues and their sources
  • SignalVu software provides wideband spectral analysis and measurements, with options for audio, modulation, RF pulses and settling time
  • TekScope AnywhereTM software enables offline measurements and analysis

Powerful triggering makes capture easy

Thumbnail

Easily capture signal anomalies, including glitches, runts, setup/hold violations and NRZ pattern lock for serial data streams up to 1.25 Gb/s, with Pinpoint® triggering and Visual Trigger and Search.

Highlights

  • More than 1,400 available trigger combinations
  • Quickly define complex triggers and search criteria graphically with Visual Trigger
  • Optional serial triggers provide protocol-aware signal capture capabilities

Serial analysis and compliance testing, done right

Thumbnail

Simplify advanced system design debug and verification with protocol decode and serial trigger options for low- and mid-speed buses. Ensure interoperability of mid-speed serial buses with automated compliance testing.

Highlights

  • Protocol decode with serial triggering and analysis options available for I2C, SPI, RS-232/422/485/UART, USB 2.0, Ethernet, MIL-STD-1553B, CAN, LIN, and FlexRay
  • Automated compliance testing packages available for USB 2.0, Ethernet, HSIC, MOST, and BroadR-Reach

Automated power measurements

Thumbnail

Automated measurements and reporting ensure simple, repeatable power quality, switching loss, magnetic loss, harmonics measurements and more meet the measurement demands of today’s efficient power converters. Plus, smart TekVPI current and differential probes reduce uncertainty and eliminate power measurement pitfalls.

Highlights

  • MOSFET switching loss and safe operating area analysis
  • Power factor and harmonics measurements for IEC61000-3-2 pre-compliance
  • In-circuit inductor and transformer loss measurements
  • USB power adapter compliance testing to USB2.0 Battery Charger Specification v1.1 and IEC 62684

Models

Model Analog Bandwidth Sample Rate Record Length Analog Channels List Price
DPO7054C 500 MHz 5 GS/s - 20 GS/s 25M points - 250M points 4
-
Configure & Quote
DPO7104C 1 GHz 5 GS/s - 20 GS/s 25M points - 250M points 4
-
Configure & Quote
DPO7254C 2.5 GHz 10 GS/s - 40 GS/s 25M points - 500M points 4
-
Configure & Quote
DPO7354C 3.5 GHz 10 GS/s - 40 GS/s 25M points - 500M points 4
-
Configure & Quote
Model DPO7054C
Analog BandwidthSample RateRecord Length
500 MHz5 GS/s - 20 GS/s25M points - 250M points
Analog Channels
4
Model DPO7104C
Analog BandwidthSample RateRecord Length
1 GHz5 GS/s - 20 GS/s25M points - 250M points
Analog Channels
4
Model DPO7254C
Analog BandwidthSample RateRecord Length
2.5 GHz10 GS/s - 40 GS/s25M points - 500M points
Analog Channels
4
Model DPO7354C
Analog BandwidthSample RateRecord Length
3.5 GHz10 GS/s - 40 GS/s25M points - 500M points
Analog Channels
4
Model Analog Bandwidth Sample Rate Record Length Analog Channels List Price
DPO7054C 500 MHz 5 GS/s - 20 GS/s 25M points - 250M points 4
-
Configure & Quote
DPO7104C 1 GHz 5 GS/s - 20 GS/s 25M points - 250M points 4
-
Configure & Quote
DPO7254C 2.5 GHz 10 GS/s - 40 GS/s 25M points - 500M points 4
-
Configure & Quote
DPO7354C 3.5 GHz 10 GS/s - 40 GS/s 25M points - 500M points 4
-
Configure & Quote
Model DPO7054C
Analog BandwidthSample RateRecord Length
500 MHz5 GS/s - 20 GS/s25M points - 250M points
Analog Channels
4
Model DPO7104C
Analog BandwidthSample RateRecord Length
1 GHz5 GS/s - 20 GS/s25M points - 250M points
Analog Channels
4
Model DPO7254C
Analog BandwidthSample RateRecord Length
2.5 GHz10 GS/s - 40 GS/s25M points - 500M points
Analog Channels
4
Model DPO7354C
Analog BandwidthSample RateRecord Length
3.5 GHz10 GS/s - 40 GS/s25M points - 500M points
Analog Channels
4
  Tektronix
DPO7000C
Tektronix
MSO/DPO5000B
Keysight
S Series
LeCroy
HDO6000
Bandwidth 500 MHz to 3.5 GHz 350 MHz to 2 GHz 500 MHz to 8 GHz 350 MHz to 1 GHz
Analog Channels 4 4 4 4
Analog Sample Rate (All Channels) Up to 10 GS/s Up to 5 GS/s Up to 10 GS/s Up to 2.5 GS/s
Analog Sample Rate (1 Channel) Up to 40 GS/s Up to 10 GS/s Up to 20 GS/s Up to 2.5 GS/s
Maximum Optional Record Length (1 Channel) 500 M 250 M 100 M 250 M
Waveform Capture Rate (wfms/s) >310,000 >250,000 Not Specified Not Specified
Operating System Windows Windows Windows Windows

 

Automated power measurements

Thumbnail

Automated measurements and reporting ensure simple, repeatable power quality, switching loss, magnetic loss, harmonics measurements and more to meet the measurement demands of today’s efficient power converters. Plus, smart TekVPI current and differential probes reduce uncertainty and eliminate power measurement pitfalls.

Highlights

  • Opt. PWR: Advanced power measurement and analysis solution for characterization and testing of power devices and power supplies including power quality and harmonic testing
  • Opt. USBPWR: Automated compliance testing for USB power adapters to USB2.0 Battery Charger Specification v1.1 and IEC 62684

Automotive serial analysis and compliance testing

Thumbnail

Simplify automotive system design debug and verification with protocol decode and serial trigger options for CAN, LIN and FlexRay buses. Ensure interoperability of BroadR-Reach and MOST serial devices with automated compliance testing.

Highlights

  • Opt. SR-AUTO: CAN, LIN, and FlexRay protocol trigger and decode of serial packet content
  • Opt. BRR: BroadR-Reach/100BASE-T1 and 1000BASE-T1 Automated Compliance Solution
  • Opt. MOST: Electrical compliance and debug test solution for MOST50 and MOST150 host and device designs

Embedded serial decoding and analysis

Thumbnail

Protocol decode, serial triggering, and analysis for I2C, SPI, RS-232/422/485/UART, USB 2.0, Ethernet, and MIL-STD-1553B simplify advanced system design debug and verification.

Highlights

  • Opt. SR-AERO MIL-STD-1553B protocol trigger and decode of serial packet content
  • Opt. SR-COMP RS-232/422/485/UART protocol trigger and decode of serial packet content
  • Opt. SR-DPHY MIPI® D-PHY automatic decode and search on serial packet content
  • Opt. SR-EMBD I2C and SPI protocol trigger and decode of serial packet content
  • Opt. SR-ENET 10BASE-T and 100BASE-TX protocol search and decode of serial packet content
  • Opt. SR-USB USB 2.0 low-speed, full-speed and high speed protocol trigger and decode of serial packet content

Serial compliance testing

Thumbnail

Ensure interoperability of USB 2.0 and Ethernet serial designs with automated compliance testing.

Highlights

  • Opt. ET3 Automated characterization, compliance and full PHY layer support for 10BASE-T, 100BASE-TX and 1000BASE-T
  • Opt. USB2 Perform "one touch" compliance testing with automated instrument and test mode control
  • Opt. HSIC Electrical signal quality test and protocol validation of HSIC host and device designs
  • Opt. DDRA Complete memory interface analysis package for DDR1/2/3/4, LPDDR1/2/3/4 and GDDR3/5

Advanced jitter and timing analysis

Thumbnail

With comprehensive jitter and eye-diagram analysis, plus decomposition algorithms, DPOJET simplifies discovering signal integrity concerns and jitter and their related sources in today's high-speed serial, digital and communication system designs.

Highlights

  • Characterize performance of high-speed serial and parallel bus designs
  • Characterize clock and data jitter/noise and signal integrity
  • Characterize modulation of spread spectrum clock circuits
  • Perform PHY testing of serial standards such as MIPI® D-PHY, DDR and MOST

Wideband RF analysis

Thumbnail

SignalVu RF and vector signal analysis software provides the functionality of a vector signal analyzer and spectrum analyzer, with the powerful trigger capabilities of a digital oscilloscope—all in a single package. Use SignalVu to easily validate wideband designs and characterize wideband spectral events.

Highlights

  • Opt. SVE: SignalVu Essentials provides wideband spectral analysis and measurements
  • Opt. SVA: SignalVu AM/FM/Direct audio measurements
  • Opt. SVM: SignalVu general-purpose modulation analysis
  • Opt. SVP: SignalVu advanced pulse signal analysis
  • Opt. SVT: SignalVu settling time measurements–frequency and phase
Data SheetSoftware Package / Software OptionDescriptionConfigure and Quote
Opt. BRR

BroadR-Reach/100BASE-T1 and 1000BASE-T1 Automated Compliance Solution.

Contact Us
Opt. CMENET3

TekExpress Ethernet Automated 10/100/1000 BASE-T Compliance Testing Solution

Contact Us
Opt. D-PHY

Verify to the MIPI D-PHY specification by rapidly characterizing and discovering sources of jitter and signal integrity concerns using the fully flexible and customizable test setup. Using DPOJET, Option D-PHY enables transmitter high-speed data-clock timing measurements, along with a full range of electrical characteristics in high-speed or low-power modes.

Contact Us
Opt. DDRA, LP-DDR4

Complete memory interface analysis package for DDR1/2/3/4, LPDDR1/2/3/4 and GDDR3/5. Option LP-DDR4 for LPDDR4 is available to use only on MSO/DPO70000 oscilloscopes.

Contact Us
Opt. DJA, DJAN

Simplifies identifying signal integrity concerns, jitter and their related sources and provides the highest sensitivity and accuracy available for real-time oscilloscopes.

Contact Us
Opt. ET3

Automated characterization, compliance and full PHY layer support for 10BASE-T, 100BASE-TX and 1000BASE-T.

Contact Us
Opt. MOST

Electrical compliance and debug test solution for MOST50 and MOST150 host and device designs.

Contact Us
Opt. MTM

Compliance verification and interoperability testing to communication and computing serial standards masks.

Contact Us
Opt. NBASET NBASE-T TekExpress Conformance and Debug Solution Contact Us
Opt. PWR

Power measurement and analysis solution for characterization and testing of power devices and power supplies including power quality and harmonic testing.

Contact Us
High Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
P5100A High Voltage Probe: 500 MHz, 100X, 2.5 kV, Single-ended, BNC Configure & Quote
P6015A PROBE HIVOLTAGE; 75MHZ,40KV,1000X 10 FT - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD Configure & Quote
Passive Probe
Datasheet LinkProbeDescriptionConfigure and Quote
P6101B Probe, Passive; 15 MHz, 1X Configure & Quote
P6139B Passive Probe: 500 MHz, 10X, BNC Configure & Quote
Low Voltage Single Ended Probes
Datasheet LinkProbeDescriptionConfigure and Quote
P6243 Active Probe: 1 GHz, 10X, Single-ended, TekProbe Configure & Quote
P6245 PROBE,FET ACT; >1.5GHZ,10X, Configure & Quote
TAP1500 Active Probe: 1.5 GHz, 10X, Single-ended, TekVPI Configure & Quote
TAP2500

Active Probe: 2.5 GHz, 10X, Single-ended, TekVPI

Configure & Quote
TAP3500

Active Probe: 3.5 GHz, 10X, Single-ended, TekVPI

Configure & Quote
Low Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
P6247 PROBE,DIFF,ACT; 1GHZ BW,+/- 0.85/8.5V,1PF,TPI - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD Configure & Quote
P6248 PROBE; 1.7GHZ DIFFERENTIAL - CERTIFICATE OF TRACEABLE CALIBRATION STANDARD Configure & Quote
TDP1500

Differential Probe: 1.5 GHz, 1X/10X, +/-8.5V, TekVPI

Configure & Quote
TDP3500

Differential Probe: 3.5 GHz, 5X, +/- 2V, TekVPI

Configure & Quote
Current Probe
Datasheet LinkProbeDescriptionConfigure and Quote
TCP0020 Probe, AC/DC Current; 20 Amp; 50 MHz BW; TekVPI Interface; Certificate of Traceable Calibration Standard Configure & Quote
TCP0030A Probe, AC/DC Current; 30 Amp DC, DC TO 120 MHZ; with TekVPI Interface; Certificate of Traceable Calibration Standard Configure & Quote
TCP0150 Current Probe: 20 MHz, 5 mA to 212 A, AC/DC, TekVPI Configure & Quote
TCP202A Probe, AC/DC Current; DC coupled, 15 Amp Max DC; 50 MHz BW, TekProbe Lvl2 Interface; Certificate of Traceable Calibration Standard Configure & Quote
High Voltage Differential Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TDP0500

Differential Probe: 500 MHz, 5X/50X, +/- 42V, TekVPI

Configure & Quote
TDP1000 Differential Probe: 1 GHz, 5X/50X, +/- 42V, TekVPI Configure & Quote
THDP0100 Differential PROBE; 100 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE Configure & Quote
THDP0200 Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL HIGH VOLTAGE PROBE Configure & Quote
TMDP0200 Differential PROBE; 200 MHZ TekVPI DIFFERENTIAL MEDIUM VOLTAGE PROBE;TMPD0200 Configure & Quote
Isolated Probes
Datasheet LinkProbeDescriptionConfigure and Quote
TIVH02

IsoVu optically isolated differential probe, 200 MHz, TekVPI, 3 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips

Configure & Quote
TIVH02L

IsoVu optically isolated differential probe, 200 MHz, TekVPI, 10 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips

Configure & Quote
TIVH05

IsoVu optically isolated differential probe, 500 MHz, TekVPI, 3 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips

Configure & Quote
TIVH05L

IsoVu optically isolated differential probe, 500 MHz, TekVPI, 10 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips

Configure & Quote
TIVH08

IsoVu optically isolated differential probe, 800 MHz, TekVPI, 3 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips

Configure & Quote
TIVH08L

IsoVu optically isolated differential probe, 800 MHz, TekVPI, 10 m cable, includes 50X(MMCX50X) and 500X(SQPIN500X) tips

Configure & Quote
TIVM1

IsoVu optically isolated differential probe, 1 GHz, TekVPI, 3 m cable, includes 5X(IVTIP5X) and 25X(IVTIP25X) tips

Configure & Quote
TIVM1L

IsoVu optically isolated differential probe, 1 GHz, TekVPI, 10 m cable, includes 5X(IVTIP5X) and 25X(IVTIP25X) tips

Configure & Quote
TekExpress
This document contains information on the available MHL (Mobile High-Definition Link) test adapters and test fixture kits. These test adapters and test kits provide electrical test interfaces for MHL technology.
Part number: 071301300
User
TekExpress
TekExpress is the Tektronix Compliance Test Automation Framework, developed to support current and future test automation needs of customers. The MHL solution supports test automation in the TekExpress framework providing customers with a complete…
Part number: 077062001
Online Help
Session Exporter tool for TekScopeAnywhere, TM

Part number: 066177200
Application
TekScope Anywhere, TM

Part number: 066177100
Application
MSO70000DX, DPO70000DX, MSO70000C, DPO70000C, DPO7000C, MSO5000B, and DPO5000B Series
This manual describes the installation and operation of MSO/DPO70000DX Series, MSO/DPO70000C Series, DPO7000C Series, MSO5000B Series, and DPO5000B Series instruments. Basic operations and concepts are presented in this manual.
Part number: 071298004
Primary User
TekExpress
TekExpress is the Tektronix Compliance Test Automation Framework, developed to support current and future test automation needs of customers.
Part number: 077062102
Primary User
Reference Waveform File Format
This document specifies the reference waveform file format for the instrument.
Part number: 077022005
Programmer
016-1983-02, 016-1985-02, and 016-1988-02 and above
This document supports installing Tektronix DPO7000/C, DPO70000/B/C/D/DX, DSA70000/B/C/D, MSO70000/C/DX, AWG5000, and AWG7000 Series instruments in a standard 19-inch equipment rack.
Part number: 075103901
Field Install Instructions
DPO7000/C, DPO70000/B/C/D/DX, DSA70000/B/C/D, MSO70000/C/DX, MSO5000/B, and DPO5000/B Series
This document helps customers with data security concerns to sanitize or remove memory devices from the DPO5000, DPO5000B, DPO7000C, DPO7000, DPO70000, DPO70000B, DPO70000C, DPO70000D, DPO70000DX, DSA70000, DSA70000B, DSA70000C, DSA70000D, MSO5000,…
Part number: 077024507
Declassification
MSO/DPO70000DX, MSO/DPO70000C, DPO7000C, MSO5000B, and DPO5000B Series
This document provides user information for Tektronix MSO70000C, DSA70000C, DPO70000C, MSO5000B, DPO5000B, and DPO7000C instruments.
Part number: 077006214
Online Help
DDR
DDR Analysis is a standard specific solution tool for Tektronix Performance Digital Oscilloscopes(DPO7000, DSA/DPO/MSO70000/B series). DDR Analysis requires Jitter and Eye Diagram Analysis Tool (Opt.DJA) and the advanced Search and Mark capability (Opt.…
Part number: 077023108
Online Help
TekExpress
TekExpress is the Tektronix Compliance Test Automation Framework, developed to support current and future test automation needs of customers.
Part number: 077092600
Online Help
Best Practices
This document summarizes the Best Practices for using Tektronix MSO70000/C, DPO7000/C, DPO70000/B/C/D and DSA70000/B/C/D Series products.
Part number: 071298903
User
TekExpress
TekExpress is the Tektronix Compliance Test Automation Framework, developed to support current and future test automation needs of customers.
Part number: 077062101
Primary User
ADK
This document is a printable version of the online help. The Application Developer Kit (ADK) provides tools for oscilloscope users and third parties to create custom applications for Tektronix oscilloscopes. ADK provides developers fast access to waveform…
Part number: 077069300
User
MOS/DPO70000DX, MSO/DPO70000C, DPO7000C, MSO5000/B, and DPO5000/B Series
This programmer manual provides you with the information required to use Programmable Interface commands for remotely controlling your instrument (MSO70000/C/DX, DPO70000/B/C/D/DX, DSA70000/B/C/D, DPO7000/C, MSO5000/B, DPO5000/B).
Part number: 077001018
Programmer
TekExpress
TekExpress is the Tektronix Compliance Test Automation Framework, developed to support current and future test automation needs of customers.
Part number: 077062100
Online Help
MSO/DPO70000DX, DSA/DPO70000D, MSO70000/C, DSA/DPO70000B/C, DPO7000/C, MSO5000/B, and DPO5000/B Series This manual contains service information for your instrument.
This manual contains service information for your instrument.
Part number: 077007610
Service
TEKVISA CONNECTIVITY SOFTWARE, V4.0.4

Part number: 066093809
Driver
Tektronix Toolbars for Microsoft Office, V4.0.4
Tektronix Toolbars for Microsoft Office, V4.0.4
Part number: 066133202
Utility
DPOJET - DPO7000-C, DPO-MSO5000, DPO-DSA-MSO70000-B-C-D Win XP - Win 7

Part number: 066141600
Application
DPOJET - DPO7000-C, DPO-MSO5000, DPO-DSA-MSO70000-C-D - Win 7, V6.0.1

Part number: 066152100
Application
MOST Essentials - Electrical Compliance and Debug Test Solution for MOST50 and MOST150 - DPO-MSO5000,DPO-MSO5000B, DPO7000C, DPO-DSA-MSO70000C-D - Win7 V6.0.2
MOST Essentials - Electrical Compliance and Debug Test Solution for MOST50 and MOST150 - DPO-MSO5000,DPO-MSO5000B, DPO7000C, DPO-DSA-MSO70000C-D - Win7 V6.0.2
Part number: 066142803
Application
Tektronix Simplifies Serial Bus Debug to Drive Engineering Productivity
Rolls Out Significant Upgrades to Popular DPOJET Analysis Toolset, Enhances Serial Analysis Capabilities, Expands Automobile Industry Bus Support
News Release 17 Jan 2016
DPOJET Deployment Package - DPO7000-C, DPO-MSO5000-B, DPO-DSA-MSO70000C-D-DX - Win 7, V7.0.1

Part number: 066164502
Application
DPOJET - DPO7000-C, DPO-MSO5000, DPO-DSA-MSO70000-C-D - Win 7, V6.0

Part number: 066145300
Application
MOST Essentials - Electrical Compliance and Debug Test Solution for MOST50 and MOST150 - DPO-MSO5000,DPO-MSO5000B, DPO7000C, DPO-DSA-MSO70000C-D - Win7 V6.0.1

Part number: 066142801
Application
Deployment Package for DPO7KC, DPO-DSA-MSO70KC and DPO-DSA70KD Win7 series oscilloscopes V6.8.1

Part number: 066141804
Firmware
Application Development Kit DPO-MSO5K, DPO7KC, DPO-DSA-MSO70KC,D,DX Win7 V1.2.0

Part number: 066142101
Application
TekExpress D-PHY TX Automated Solution DPO7000-C, DPO-DSA-MSO70000-B-C-D - Win XP - Win7, V3.1.0

Part number: 066152200
Application
REPORT GENERATOR V3.03.002-DPO7000,DPO7000C,DPO-MSO5000,DPO-DSA70000,DPO-DSA70000B,DPO-DSA70000C,MSO70000-C,TDS7000,TDS7000B,CSA7000,CSA7000B,TDS6000,TDS6000B,TDS6000C-WinXP-Win7 V3.03.002

Part number: 066077407
Application
TDSPTD - DPO7254-C, DPO7354-C, DPO-DSA-MSO70000-B-C - Win XP - Win 7

Part number: 066063709
Application
TEKTRONIX TEKScope IVI Driver V3.7

Part number: 066045313
Driver
TDSET3 Ethernet Compliance SW DPO-DSA-MSO5000-7000-70000-B-C-D - WinXp, Win7 V3.2.5

Part number: 066079617
Application
TekExpress Ethernet (1000BASE-T,100BASE-TX and 10BASE-T) Compliance Solution - DPO-MSO 5000B-7000C-70000C-DX-SX - V10.2.1
With TekExpress Ethernet Compliance Test Software, engineers validating an Ethernet physical layer can perform reliable compliance tests of 10Base-T, 100Base-TX and 1000Base-T technologies in their labs. This application enhances efficiency with faster…
Part number: 066196756
Application
Ensuring the Performance and Conformance of In-Vehicle Networks for New-Generation Automobiles
Automotive Primer: In-Vehicle NetworkingThis primer provides an overview of the trends, challenges and solutions associated with the expected future evolution of in-vehicle networks, as well as a foundation for testing in-vehicle networks to accelerate new designs to production, streamline…
Literature number: 48W-61611-0
Primer 30 Aug 2019
Oscilloscope Selection Guide
From basic signal-checking to high-performance analysis, this selection guide gives an overview of the complete range of oscilloscopes from Tektronix.
Literature number: 46W-31080-5
Selection Guide 29 Aug 2019
XYZs of Oscilloscopes Primer
After reading this primer, you will be able to: Describe how oscilloscopes work, Describe the differences between analog, digital storage, digital phosphor, and digital sampling oscilloscopes, describe electrical waveform types, understand basic…
Literature number: 03Z-8605-7
Primer 27 Aug 2019
TEKVISA Connectivity Software - V4.2.0
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various…
Part number: 066093812
Driver
SignalVu - DPO7000C - DPO-DSA-MSO70000C - DPO-DSA70000D - DPO-MSO70000DX - DPO70000SX - DPO-MSO5000 - V3.23.0022
SignalVu Vector Signal Analysis (ver 3.23) runs as an option to the DPO7KC, DPO-DSA-MSO70KC, DPO-DSA70KD,DPO-MSO70KDX, DPO70000SX and DPO-MSO5K(64-bit systems) series scopes.
Part number: 066179007
Application
DPOPWR Advanced Advanced Power Analysis Software
DPOPWR is a power measurement and analysis software that runs on MSO/DPO5000/B, DPO7000/C, MSO/DSA/DPO70000/C/D, and MSO/DPO70000DX series oscilloscopes. DPOPWR allows you…
Part number: 077001810
User
Power Supply Measurement and Analysis Primer
This primer focuses on switch-mode power supply design measurements using an oscilloscope and application-specific software.
Literature number: 55T-18412-6
Primer 15 Aug 2019
TDSET3 Ethernet Compliance SW DPO-MSO5000B, DPO7000C, DPO-DSA-MSO70000C Series and DPO-DSA-MSO-70000D-DX-SX - v3.2.10
With Ethernet Compliance Test Software, engineers validating their Ethernet physical layer can perform reliable compliance tests of 10BaseTe, 10BaseT, 100Base-TX, and 1000BaseT technologies in their labs. This application enhances efficiency with faster…
Part number: 066180101
Application
How to Use a Link Partner in Testing with TDSET3
*/ /*-->*/ Several of the tests in Ethernet Compliance Testing can be performed using a Link Partner (especially in 10BASE-T). This is useful when the test requires the Device Under Test (DUT) to generate a pseudo-random sequence, but you do not have…
FAQ ID: 468146 14 Aug 2019
Digital Phosphor Oscilloscopes
DPO7000 Series Datasheet Tektronix understands that engineers rely on an oscilloscope throughout their design cycle, from prototype turn-on to production testing. The DPO7000 Series oscilloscopes' unique capabilities combined with exceptional signal acquisition performance and an…
Literature number: 48W-26543-21
Datasheet
How to replace the CMOS battery on DPO/DSA 7000/70000 Series Oscilloscopes.
You may need to change the CMOS battery on the motherboard.  Refer to attached instructions for changing the battery and resetting the CMOS. Refer to the respective instrument service manual for instructions how to gain access to the instrument…
FAQ ID: 72171 09 Aug 2019
Which probes are compatible with oscilloscopes with the TekVPI probe interface?
There are a couple different types of TekVPI interfaces, one with a notch and one without. The notch was implemented later and was put in place because the front end was designed differently and communicates uniquely with those types of probes. …
FAQ ID: 56226 08 Aug 2019
What are some of the benefits of the TekVPI probe interface?
The biggest benefits of the TekVPI™ probe interface are versatility and ease of use. Oscilloscopes with TekVPI interface support a wide range of probes including TekVPI probes, BNC and TekProbe-BNC Level 1 probes, and TekProbe-BNC Level 2 probes (via a…
FAQ ID: 56016 05 Aug 2019
Making Accurate Current Measurements on Power Supplies with Oscilloscopes
Learn how to measure current using shunt resistors and voltage probes, and how to use clamp-on current probes with your oscilloscope. Get tips on improving the resolution of your current measurements and avoiding common pitfalls.
Literature number: 51W-60171-2
Application Note 30 Jul 2019
TEKVISA CONNECTIVITY SOFTWARE - V4.1.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various…
Part number: 066093811
Driver
I downloaded and Installed OpenChoice Desktop, but it doesn't recognize my scope.
Refer to the Prerequisites.txt file available to download on the same page for OpenChoice desktop. Make sure you have all the prerequisites specified.    Prerequisites 1. PC equipped with  Microsoft Windows 7 32 Bit and 64 Bit OS, Windows 8.1 32 Bit and…
FAQ ID: 474266 30 Jul 2019
Serial Support Using Tektronix Oscilloscopes and Optional Software
Tektronix oscilloscopes offer a portfolio of optional analysis capabilities to simplify serial bus debug or compliance verification. This selection matrix shows which serial standards are supported by each of the oscilloscope series.
Literature number: 55W-29028-12
Selection Guide 30 Jul 2019
In-circuit Measurement of Inductors and Transformers with an Oscilloscope
Get a quick review of inductor and transformer theory, and learn how to use an oscilloscope with power analysis software to perform dynamic inductance measurements under operating conditions.
Literature number: 55W-61401-2
Application Note 29 Jul 2019
The data sheet for my oscilloscope says that the vertical input sensitivity is 1 mV/div to 10 V/div in 1 MΩ mode. But I turn the Vertical Scale control fully clockwise and I can only get down to 10 mV/div. What am I doing wrong?
You probably aren't doing anything wrong. But you do have a 10X probe attached to that channel, right? The 1 mV/div specs relate to the oscilloscope inputs. If the signal’s source impedance is relatively low (<< 1 MOhm), the signal’s frequency is…
FAQ ID: 58571 29 Jul 2019
Downloads
Download

Download Manuals, Datasheets, Software and more:

Go to top